Filter Results By:

Products

Applications

Manufacturers

Showing results: 1516 - 1530 of 1632 items found.

  • PXI 1A Fault Insertion Switch 11-Channel

    40-195-101 - Pickering Interfaces Ltd.

    The 40-195 is a 22 Channel Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions on pairs of signals between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Relays in-line with the signal paths allow open circuit conditions to be simulated on either side or both sides of a signal pair. Relays between each channel pair enable adjacent signals to be shorted, and relays between signal paths and the "Fault" connection allow the application of external user applied fault conditions.

  • Rubber Testing Equipment

    Dongguan Amade Instruments Technology Co., Ltd

    Rubber testing equipment are used to test the physical properties, chemical properties, thermal properties of uncompounded and compounded rubbers at prescribed conditions to help manufactures or researchers in comprehending the characteristics, updating the formula and improving product quality. Including volatile component, ash content, Mooney viscosity, vulcanization curve, Mooney scorch time, hardness, tensile properties, tearing, the compression performance, impact, friction resistance, fatigue resistance, peel strength, vertical & horizontal combustion, smoke density, limiting oxygen index, the flame spread rate, the surface resistance, surface resistivity, volume resistivity, the breakdown voltage, dielectric strength, dielectric loss, antistatic properties, Aging test (UV, Xenon lamp, carbon arc lamp, ozone) etc.

  • Torque Analyzers & Sensors

    Mountz Inc.

    If torque tools slip out of calibration, that could impact the quality of your products. Having an accurate way to regularly test calibration onsite is a great way to reduce risk and ensure safety. With Mountz torque analyzers and sensors, you can test tools before they go into service every day. This prevents employees from working with miscalibrated tools and enhances quality management. It’s also more efficient to use your own torque testing equipment since you can evaluate your tools without sending them to a laboratory. Whether you want stand-alone sensors for hand and power torque tools or run down adapters that simulate actual joint conditions, Mountz has many options to choose from.

  • Harmonic/Flicker Analyzer for IEC61000-3-2/3/11/12, IEC61000-4/7/15

    KHA3000 - Kikusui Electronics Corp.

    KHA3000, in addition to the complied standards and features of the KHA1000 (dedicated for single phase), is equipped for the harmonic and flicker compliance test exceeding 16A of the single-phase and three-phase equipment. With this unit alone, you can take highly accurate simultaneous three-phase measurements up to 40A/phase*. Furthermore, the KHA series is compliant with two measurement technique standards, the existing and the latest versions, so you can simply select to take measurements for the latest standard including interharmonics and for the conventional integral multiple harmonics without using any other device. In addition to the real-time display that can be used like an oscilloscope and FFT analyzer, the unit offers the real-time judgment of compliance with standards. Using this unit alone, you can judge test results and prepare result reports without the use of a PC. On top of that, you can easily set up a test system by combining KHA3000 with an AC power supply (PCR-LA Series) and a line impedance network (LIN40MA-PCR-L).

  • UNI-T Series

    Weshine Electric Manufacturing Co., Ltd

    mainly used to measure the wire resistance of cables, the contact resistance ofswitches, connectors, relays, the resistance of coils, motors, transformer windings, and equipment enclosures, lightning protection belts, ground beams, structures, cabinets, steel bars, Test the connection resistance between metal components of water pipes, windows, guardrails, radiators, assembly lines, etc. It is widely used in telecommunications, electric power, meteorology, computer rooms, oil fields, power distribution lines, tower transmission lines, gas stations, factory grounding grids, lightning rods, etc.

  • Authorized GPS AES M-Code Testing

    SimMCODE - Spirent Federal Systems

    Validate M-Code functions via AES M-code protocols for high fidelity secure testing. In order to facilitate greater accuracy and robustness than available in civilian GNSS, the US government has long provided secure signals for authorized users. M-Code is the latest iteration of this process, providing an encrypted and standalone service (unlike the P(Y)-Code). Spirent’s SimMCODE enables authorized users to thoroughly test Military GPS User Equipment (MGUE) in repeatable, lab-based environments, using the commercial encryption algorithm, Advanced Encryption Standard (AES).

  • Asphalt Testing Equipment

    ELE International

    ELE international manufactures a comprehensive range of field and laboratory asphalt testing equipment to ensure compliance with quality and performance specifications. Traditional methods of binder content analysis involved the use of solvents, but due to environmental concerns ELE has developed an Asphalt Binder Analyser which uses an ignition method and thereby avoids the use of harmful solvents. Loss on heating and a rolling thin-film oven are used for testing bitumen, flash and fire point are measured with the Cleveland Flash Cup Apparatus, and the Ring and Ball test enables the measurement of the softening point.

  • Nuclear EMC Testing Services

    Washington Laboratories LTD.

    The implementation of digital control and monitoring systems in nuclear power plants drives EMC requirements for new and replacement equipment to be used in nuclear plants. For the past 20 years, the Electric Power Research Institute (EPRI) has been developing test methods to demonstrate compliance with EMC requirements. The methods and limits are called out in EPRI TR-102323. The first issue of this report was released in 1994 and the current revision (Revision 4) was released in 2013. The original report and basis included results from electromagnetic surveys at seven nuclear power plants in the United States.

  • Failure Analysis

    Pacific Testing Laboratories

    A partial list of our state of the art test equipment, applicable to these testing disciplines, will include the following: Two Scanning Electron Microscopes with EDS (SEM/EDS) Three Differential Scanning Calorimeters (DSC) Three Thermogravimetric Analyzers (TGA) Three Thermo Mechanical Analyzers (TMA) One Dynamic Mechanical Analyzer (DMA) Two Real-Time Fluoroscopic X-ray Systems, including a Microfocus System One Fourier Transform Infrared Microscope (FTIR) (capable of identifying a single particle of an unknown material) Two Ion Chromatographs (IC) (capable of identifying ionic impurities in ppm)

  • Gloss & Reflectance

    Elcometer Limited

    Visual appearance can determine a person’s perception of a product. Colour and Gloss are two key parameters that are used to define a product’s overall quality. Perception is subjective, but Elcometer’s range of gloss meters, DOI meters and colour assessment equipment can quantify appearance measurement. The ability of a surface to reflect light without scattering is known as gloss. Using a gloss meter, gloss is measured by directing a constant intensity light beam at a fixed angle to the test surface and then by monitoring the amount of reflected light at the same angle. Different surfaces require different reflective angles.

  • Multi-Zone Gas Monitor

    HGM-MZ - IMR Environmental Equipment, Inc.

    The Multi-Zone Monitor provides continuous detection of refrigerant gas levels in up to 16 separate test zones and can be fitted with an optional two channel 4-20 mA current loop board for connection to remote monitoring equipment. Multi-Zone monitors retain a log of previous readings that can be easily accessed for analysis. Four relay contacts are provided that can be programmed to trigger external alarm devices in the event of a system fault, or if a leak (small), spill (medium) or evacuation (large) level of gas is detected, while audible and visual front panel indicators show alarm and fault conditions.

  • BMET PACK PRO

    Pronk Technologies Inc.

    BMET PACK PRO, a compact pack for all Pronk products and accessories with extra space for tools and 15.6-in. PC/tablet compartment. Includes the world’s smallest simulators — SC-5 SimCube® NIBP, OX-2 OxSim Flex® SpO2, and SimSlim® Multi-parameter — plus the new Safe-T Sim® Automated Safety Analyzer and next-gen FT-2 FlowTrax® IV Pump Analyzer with Pressure and Temperature Meters. With customized padded compartments, the BMET PACK PRO makes it easier than ever to travel with all your test equipment between hospitals and clinics.

  • HIPOT Insulation Testers

    Laycock Systems

    Crown high voltage, transformer type hipot insulation testers are safe, easy to use for quick, positive determination of grounds, shorts, and broken wires in motors, transformers and other low voltage equipment or wiring systems. A turn of the selector switch gives a selection of seven voltages; 500, 1080, 1250, 1500, 1750, 2000 or 2500 volts calibrated to +/- 5% accuracy; NEMA recommendation for insulation test is twice normal voltage plus 1000 volts. Since this instrument has a capacity of 2500 volts, it readily accommodates all normal requirements.

  • Test House Services

    TS Space Systems

    At TS-Space Systems we have over 30 years experience in designing, building and operating vacuum systems for space simulation and materials testing. We have three in-house thermal vacuum chambers which are configurable for a range of temperatures for either monitored vacuum bakeout or thermal vacuum cycling. We design, build and operate these systems in-house which means we are more flexible than most test houses and are happy to modify feedthroughs, manufacture additional support equipment and even change the operation of the chambers, where possible, in order to accomodate customer requirements.

  • SART Tester

    Aeromarine SRT Ltd

    The International Marine Organization states that all GMDSS equipment (including SARTs) should be periodically maintained and verified to meet all the performance requirements. In case of test failure, ships may be detained in a port under SOLAS regulation IV/15.8.The 9GHz Search and rescue radar transponder (radar-SART) is indispensable safety device and it must be checked regularly or annually during radio inspection.The purpose of an annual testing is to determine that SART is operational as defined in appropriate performance standards for Survival Craft Radar Transponders for use in Search and Rescue Operations, IMO Resolution A.802 (19).

Get Help